Quick Facts
• Size from 450 to 2000
• Capacity up to 430,000 m3/h
• Static pressure up to 2200 Pa
• Suitable for clean air normal ventilation and smokespill application.
Operating Temperature
• Normal Ventilation: -20°C to +55°C
• High Temperature Application: available up to 300°C/2Hrs.
Motor
Totally enclosed Class 'F' or 'H', with a minimum IP55 protection are
fitted as standard. Standard motor up to 2.2kW are supplied with DOL starting,
motor 3.0kW and above are with star/delta starting. Motor of other
specifications are available upon request.
Quick Facts
• Size from 450 to 2000
• Capacity up to 450,000 m3/h
• Static pressure up to 2,300 Pa
• Suitable for clean air normal ventilation and smokespill application.
Operating Temperature
• Normal Ventilation: -20°C to +55°C
• High Temperature Application: available up to 400°C/2Hrs.
Motor
Totally enclosed Class 'F' or 'H', with a minimum IP55 protection are
fitted as standard. Standard motor up to 2.2kW are supplied with DOL starting,
motor 3.0kW and above are with star/delta starting. Motor of other
specifications are available upon request.
Quick Facts
• Size from 315 to 2000
• Capacity up to 360,000 m3/h
• Static pressure up to 1,000 Pa
• Suitable for clean air normal ventilation and smokespill application.
Operating Temperature
• Normal Ventilation: -20°C to +55°C
• High Temperature Application: available up to 400°C/2Hrs.
Motor
Totally enclosed Class 'F' or 'H', with a minimum IP55 protection are
fitted as standard. Standard motor up to 2.2kW are supplied with DOL starting,
motor 3.0kW and above are with star/delta starting. Motor of other
specifications are available upon request.
Quick
Facts
• Size
from 200 to 1000 mm
• Suitable for smoke spill application
Motor
should be selected to handle air at ambient temperature based on specified air
volume & pressure. This is to allow periodic testing of the fan.
Quick Facts
• Forward/backward curved or airfoil wheel
• Size from 200 to 1000
• Capacity up to 120,000 m3/h
• Static pressure up to 1800 Pa
• Acoustic lining is available upon request
Quick
Facts
• Size from 315 to 2,000
• Capacity up to 230,000 m3/h
• Static pressure up to 2000 Pa
• Energy Efficient, Powerful and Low Noise
• Compact size and Versatile design
• Suitable for clean air standard ventilation,
commercial kitchen (grease laden air) (up to 205°C) and high temperature
smokespill application (up to 400°C/2Hours)
Quick Facts
• Size from 450 to 2000
• Capacity up to 380,000 m3/h
• Static pressure up to 2300 Pa
• High efficiency & low noise
• Suitable for ventilation and smokespill application
Motor
Totally enclosed class F
motor, to a min. IP54 protection are fitted as standard.
Standard motor up to 2.2kW
are using supplied on DOL starting. Motor 3.0kW and above star/delta starting.
Quick Facts
• Backward curved
• Size from 315 to 800
• Capacity up to 30,000 m3/h
• Static pressure up to 1,000 Pa
• Compact cabinet, easy to installation and service. suitable for clean air
Airstream operating temperatures
• Clean air standard ventilation application -20°C to +55°C.
• Kitchen (grease laden air) application up to +205°C / 400°F.
• High temperature smokespill application up to 400°C/2Hrs certified.
Motor
All CFC Series fans are supplied with a wide variety of both 1PH and 3PH AC, PM and EC, standard and high temperature rated motors.
Quick Facts
•
Backward curved wheel
• Size
from 315 to 1000 mm.
•
Capacity up to 120,000 m3/h
•
Static pressure up to 1500 Pa
• Compact
cabinet suitable for clean air standard ventilation and high temperature
smokespill application (up to 400°C/2Hours) which it is available with
insulation class F motor
Quick Facts
• Module 400-150 to 600-600
• Insertion Loss Up to 50 dB
• Performance Tested as per ISO 7235
• High Temperature Test as per EN 12101
Quick Facts
• Size
from 315 to 2000
• Insertion
loss up to 30dB
• Non-standard
sizes can also be supplied upon request.
• For
performance requirement, no longer is there the need to produce lengthy
acoustic calculations. The unique Kruger sound design system does this for you
by means of an electronic noise calculation system. For details, please contact
the Kruger technical design office.
Quick Facts
• Size from 100 to 600 mm
• Capacities to 600 m3/h
• Static pressure up to 250 Pa
• High performance with low noise level
Quick
Facts
• Size
from 200 to 400 mm
• Capacities to 6840 m3/h
• Static
pressure up to 750 Pa
• Low
noise level and easy installation
Quick Facts
• Forward curved
• Size from 140 mm to 18 inches
• Capacity up to 18,000 m3/h
• Static pressure up to 1,000 Pa
• Low noise level and easy installation
Quick Facts
• Size from 100 to 315 mm
• Capacities to 1700 m3/h
• Static pressure up to 1000 Pa
• Can be mounted in any position
Operating Temperature
- 40degC to +40degC
Motor
Enclosed, single phase, 230V, 50/60Hz external rotor type, motors
included sealed for life ball bearing assemblies and Class B, IP44 protection
with an internal automatic reset safety thermal overload protection device as
standard.
Quick Facts
• Suitable for ducted
ventilation system
• Size from 100 to 315 mm
• Capacities to 1800 m3/h
• Easy Installation and maintenance
Operating Temperature
Maximum operating temperature +40 degC
Motor
MTD Series fans are fitted
with direct connection two speed motors as standard with thermal over load
protection. All motors are suitable for speed control regulation using
electronic or auto-transformer.
Quick Facts
• Suitable for ducted
ventilation system
• Size from 100 to 315
• Capacity up to 1877 m3/h
• High performance with significant noise reduction
Motors
MTD Silent 100/2~200/2
• Speed controllable 230V
-50HZ motor, of two speed motors. IP 44.
• Motors are Class B, with
ball bearings and safety thermal overload protection.
MTD Silent 250~315
• IP 44. External terminal
box IP 55.
• Removable fan body with two speed motor, single phase 230V-50/60 Hz speed controllable, Class F, external rotor aluminium motor with capacitor and thermal protection.
Additional Information
The models offer solutions
to ventilation problems, especially in places where people work and low sound
level is required.
Quick Facts
• Size from 315 to 1000
• Capacity up to 24,000 m3/h
• Static pressure up to 185 Pa
• Low noise level with high efficiency
Quick Facts
• Module 400-150 to 600-600
• Insertion Loss Up to 50 dB
• Performance Tested as per ISO 7235
• High Temperature Test as per EN 12101
Quick Facts
• Size
from 315 to 2000
• Insertion
loss up to 30dB
• Non-standard
sizes can also be supplied upon request.
• For
performance requirement, no longer is there the need to produce lengthy
acoustic calculations. The unique Kruger sound design system does this for you
by means of an electronic noise calculation system. For details, please contact
the Kruger technical design office.
Quick Facts
• Size from 315 to 2000
• Capacity up to 360,000 m3/h
• Static pressure up to 1,000 Pa
• Suitable for clean air normal ventilation and smokespill application.
Operating Temperature
• Normal Ventilation: -20°C to +55°C
• High Temperature Application: available up to 400°C/2Hrs.
Motor
Totally enclosed Class 'F' or 'H', with a minimum IP55 protection are
fitted as standard. Standard motor up to 2.2kW are supplied with DOL starting,
motor 3.0kW and above are with star/delta starting. Motor of other
specifications are available upon request.
Quick Facts
• Size from 450 to 2000
• Capacity up to 450,000 m3/h
• Static pressure up to 2,300 Pa
• Suitable for clean air normal ventilation and smokespill application.
Operating Temperature
• Normal Ventilation: -20°C to +55°C
• High Temperature Application: available up to 400°C/2Hrs.
Motor
Totally enclosed Class 'F' or 'H', with a minimum IP55 protection are
fitted as standard. Standard motor up to 2.2kW are supplied with DOL starting,
motor 3.0kW and above are with star/delta starting. Motor of other
specifications are available upon request.
Quick Facts
• Size from 450 to 2000
• Capacity up to 430,000 m3/h
• Static pressure up to 2200 Pa
• Suitable for clean air normal ventilation and smokespill application.
Operating Temperature
• Normal Ventilation: -20°C to +55°C
• High Temperature Application: available up to 300°C/2Hrs.
Motor
Totally enclosed Class 'F' or 'H', with a minimum IP55 protection are
fitted as standard. Standard motor up to 2.2kW are supplied with DOL starting,
motor 3.0kW and above are with star/delta starting. Motor of other
specifications are available upon request.
Quick
Facts
• Size from 315 to 2,000
• Capacity up to 230,000 m3/h
• Static pressure up to 2000 Pa
• Energy Efficient, Powerful and Low Noise
• Compact size and Versatile design
• Suitable for clean air standard ventilation,
commercial kitchen (grease laden air) (up to 205°C) and high temperature
smokespill application (up to 400°C/2Hours)
Quick Facts
• Size from 450 to 2000
• Capacity up to 380,000 m3/h
• Static pressure up to 2300 Pa
• High efficiency & low noise
• Suitable for ventilation and smokespill application
Motor
Totally enclosed class F
motor, to a min. IP54 protection are fitted as standard.
Standard motor up to 2.2kW
are using supplied on DOL starting. Motor 3.0kW and above star/delta starting.
Quick Facts
• Suitable for wall or panel
mounting
• Size from 200 to 355 mm
• Capacities to 1800 m3/h
• Easy mounting and compact design
Operating Temperature
Maximum operating temperature +40degC
Motor
All models incorporate shaded pole motors with safety thermal overload fuse.
Users are informed that the data included in the contact us form will be included in a file held by Kruger Ventilation Industries Asia Co., Ltd.
Users must complete all mandatory fields of the contact us form with truthful, complete and updated information, except fields marked as optional.
The processing has the following purposes: possible sending of informative communications by email about products and services of Kruger Ventilation Industries Asia;management and response to queries submitted.
Your data may be communicated to any company from the Ferrari Asia Ventilation Group for similar purposes.
Your data will be stored for the time needed to resolve the queries submitted.
By sending your data you give your express consent to the inclusion of your data in the contact us form and to the indicated processing.
If you have any doubts about privacy, please contact the Data Protection Representative. You may exercise your rights of access, cancellation and objection in relation to your data by sending an email to: mktg@krugerventasia.co.th.
The service provider reserves the right to modify any information that may appear on this site, without any obligation to notify users beforehand or make users aware of said obligation, understanding publication on the site to be sufficient notification.
A cookie is a file that is downloaded onto your computer when you visit certain websites. Cookies allow a site, among other things, to store and recover data regarding the browsing habits of a user or computer and, depending on the information they contain and how the computer is used, they can be employed to identify the user.
This website uses analysis cookies. Analysis cookies are used internally or by third parties to quantify the number of users and thus measure and analyse how users employ the services we offer. To do this, your activity on our website is analysed in order to improve the products or services we offer you.
You can allow, block or delete cookies installed on your computer by going to your browser settings.
For more information about Internet Explorer, please click here.
For more information about Mozilla Firefox, please click here.
For more information about Google Chrome, please click here.
For more information about Safari, please click here.
Information obtained through these cookies is handled exclusively by Kruger Ventilation Industries Asia Co., Ltd.